The ElecTo SJ is the single-jet meter that offers integrated data communication thanks to its innovative multi-protocol radio electronic register. This variant is designed for both indoor and outdoor residential applications and is available for cold and hot water. The LCD display simplifies data reading and makes additional information available to users and operators. Thanks to dual wM-Bus and LoRaWan communication, it offers maximum flexibility in short and long distance data communication and can be used with both mobile and fixed reading systems.
• Electronic single jet meter
• For indoor and outdoor applications
• Available for hot and cold water
• DN: 15÷20
• MID-certified: R MAX 160
• High protection against external magnetic fields
• UV protection of display and protective cover
• Health certifications available for a number of countries
• Rotating register with IP68 rating
• Datalogging with a storage capacity of over 11,000 values
• Integrated wM-Bus, OMS and/or LoRaWAN radio
• Optimized antenna for maximum radio range
• Lithium battery with a minimum life of 13 years in dual mode (varies depending on the configuration chosen)
• Fault detection: Fraud, Probable leak, overconsumption, reverse flow, blocked meter and reversed meter
• Programming and testing kit available upon request


| Size | mm | 15 | 20 | |||
| in | 1/2 | 3/4″ | ||||
| Module B no. | TCM 142/20 – 5700 | |||||
| Module D no. | 0119-SJ-A010-08 | |||||
| Q₃/Q₁ = R Referred to installation position |
H↑ ≤ 100 H→; V↓ ≤ 50 V↑ ≤ 40 |
H↑ ≤ 160 H→; V↓ ≤ 80 V↑ ≤ 63 |
H↑ ≤ 100 H→; V↓ ≤ 50 V↑ ≤ 40 |
H↑ ≤ 160 H→; V↓ ≤ 80 V↑ ≤ 63 |
||
| MID standard performance * | ||||||
| Q₃ | m³/h | 1,6 | 2,5 | 4 | ||
| Q₄ | m³/h | 2 | 3,13 | 5 | ||
| R | 100 | |||||
| Q₁ | l/h | 16 | 15,63 | 40 | ||
| Q₂ | l/h | 25,60 | 25,01 | 64 | ||
* Other values of R available upon request.
| Maximum permissible error between Q₁ and Q₂ (excluded) |
+/- 5% | ||||||
| Maximum permissible error between Q₂ (included) and Q₄ |
+/- 2% with water temperature ≤ 30°C +/- 3% with water temperature > 30°C |
||||||
| Temperature class | T30,T50,T30/90 | ||||||
| Flow profile sensitivity classes | U0 – D0 | ||||||
| Starting flow rate | l/h | 4,5 | 8 | ||||
| Head loss | ΔP63 | ||||||
| Nominal pressure | bar | 16 | |||||
| Maximum reading | m³ | 999.999 | |||||
| Minimum reading | l | 1 | |||||
| Indicative weight | kg | 0,40 | 0,57 | ||||

| Size | mm | 15 | 20 | |||
| in | 1/2 | 3/4″ | ||||
| Thread | in | G ¾ B | G 1 B | |||
| L | mm | 80*/110/115/120/130 *only Q₃ 2,5 R ≤H100 VR63 |
80*/110/115/120/130 – *Starting flow rate 7l/h |
115/130 | ||
| H | mm | 84 | ||||
| h | mm | 16,7 | 16,7 | |||
| B | mm | 75 | ||||

For more information on all the accessories available, consult the specific technical data sheets on the website www.maddalena.it