BADGER Amplifier ModMAG® M2000 Electromagnetic meter with MID

  • DN6 – DN2000
  • High Accuracy
  • ModBus®, HART, Profibus DP, M-Bus
  • LCD display
  • Power supply 85 – 265 VAC / 9 – 36 VDC
  • IP67 housing
  • Integrated data logger
  • Verification Device

PRODUCT OVERVIEW VIDEO

 

Ask Question
Category: Product ID: 4556

Description

BADGER Amplifier ModMAG® M2000

Electromagnetic meter with MID

 

The amplifier type ModMAG® M2000 is best suited for bidirectional flow measurement of fluids with a conductivity > 5 µS/cm (> 20 µS/cm for demineralized water). ModMAG® M2000 shows a high accuracy, is easy to use and can be chosen for a large and flexible applications spectrum.

The backlit, four-line display shows all actual flow measuring data, daily and complete information, including alarm messages.

The standard amplifier has 4 programmable digital outputs, one digital input, power output and USB interface. Integrated test tools make the putting into operation and the service easier.

Medium:
Water, Liquid food
max. flow:
from 0.05 up to 2262000 l/min
Temperature:
from -40 up to 150 °C
max. pressure:
from 0 up to 100 bar
Branch:
Water & waste water industry, Food & beverage industry, Chemical industry, Automotive industry, General industry, Pharmaceutical industry

 

Measuring principle

Electromagnetic flow meters

The operating principle of the electromagnetic flow meter is based on Faraday’s law of magnetic induction: The voltage induced across any conductor, as it moves at right angles through a magnetic field, is proportional to the velocity of that conductor. The voltage induced within the fluid is measured by two diametrically opposed internally mounted electrodes. The induced signal voltage is proportional to the product of the magnetic flux density, the distance between the electrodes and the average flow velocity of the fluid.

Technical Data

 

Size DN 6 – DN 2000
Accuracy ±0,2 % of actual flow, ±1 mm/s of actual flow
Repeatability 0,1 %
Flow range 0,03 – 12 m/s
Conductivity Min. 5 μS/cm (min. 20 μS/cm for demineralized water)
Power supply 85 – 265 VAC (50/60 Hz) < 20 VA, optional 9 – 36 VDC
Display LCD 4 lines / 20 characters
Digital outputs 4 x open collector, 2 x relays
Digital inputs Yes
Analog output 0/4 – 20 mA, 0/2 – 10 mA
Interface Modbus RTU RS232/RS485, Profibus DP, M-Bus, HART®
Empty pipe detection Separate electrode
Datalogger 10.000 measuring values (optional)
Housing Aluminium, IP 67
Remote version Max. 100 m
Ambient temperature -20 °C up to +60 °C
Approvals OIML R49-1, MID MI-001

 

Accessories

Heat calculator model 212

  • Complies with OIML R75 and EN1434 standards
  • Provides multilingual capability
  • M-Bus and ModBus® RTU RS 485 options

 

 

AquaCUE® Flow measurement manager

  • Fast leak detection
  • No special infrastructure required
  • Data retrieval available anytime