BADGER Amplifier ModMAG® M1000 Electromagnetic meter

  • DN6 – DN500
  • Power supply 24 VDC / 115 VAC / 230 VAC
  • The low cost alternative
  • Accuracy ±0,5 % of actual flow
  • Flow range 0,03 – 12 m/s
  • Power supply 24 VDC / 115 VAC / 230 VAC

PRODUCT OVERVIEW VIDEO

 

Ask Question
Category: Product ID: 4551

Description

BADGER Amplifier ModMAG® M1000

Electromagnetic meter for all detectors

 

The electromagnetic flow meter ModMAG® M1000 has been designed to fit into the MAG meter series and especially for applications in machinery plants, vehicles and batching processes.

The applications range from DN 6 to DN 500 with the most various process connections like DIN flanges, dairy pipe connections, TriClamp®, etc.

The basic line of ModMAG® M1000 is provided with 24 VDC power supply, without display, with passive outputs and can be programmed via a serial port RS 232 or separate handheld. The device can also, upon request, be factory preconfigured and then just needs to be electrically connected on site.

Medium:
Water, Liquid food
max. flow:
from 0.05 up to 22700 l/min
Temperature:
from -40 up to 150 °C
max. pressure:
from 0 up to 100 bar
Branch:
Water & waste water industry, Food & beverage industry, Chemical industry, Automotive industry, General industry, Pharmaceutical industry

 

Measuring principle

Electromagnetic flow meters

The operating principle of the electromagnetic flow meter is based on Faraday’s law of magnetic induction: The voltage induced across any conductor, as it moves at right angles through a magnetic field, is proportional to the velocity of that conductor. The voltage induced within the fluid is measured by two diametrically opposed internally mounted electrodes. The induced signal voltage is proportional to the product of the magnetic flux density, the distance between the electrodes and the average flow velocity of the fluid.

 

Technical Data

 

Size DN 6 – DN 500
Accuracy ±0,3 % of actual flow,
±2 mm/s of actual flow
Repeatability 0,1 %
Flow range 0,03 – 12 m/s
Conductivity Min. 5 μS/cm (min. 20 μS/cm for demineralized water)
Power supply 92 – 275 VAC (50/60 Hz) < 14 VA, optional 9 – 36 VDC, 4 W
Display LCD graphic display
Digital outputs 2 x open collector, 1 x relay
Digital inputs Yes
Analog output 0/4 – 20 mA, 0 – 10 mA
Interface Modbus RTU RS232/RS485, ModBus®/TCP, M-Bus, HART®
Empty pipe detection Separate electrode
Datalogger 30.000 measuring values
Housing Aluminium, IP 67
Remote version Max. 50 m
Ambient temperature -20 °C up to +60 °C
Approvals